As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: RUGGEDCOM APE1808 Vulnerabilities: Insufficiently Protected Credentials, Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to escalate privilege, gain unauthorized access, or cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products using Nozomi Guardian/CMC before 23.4.1, are affected: RUGGEDCOMAPE1808LNX (6GK6015-0AL200GH0): All versions RUGGEDCOM APE1808LNX CC (6GK60150AL20-0GH1): All versions 3.2 Vulnerability Overview 3.2.1 INSUFFICIENTLY PROTECTED CREDENTIALS CWE-522 Audit records for OpenAPI requests may include sensitive information. This could lead to unauthorized accesses and privilege escalation. CVE-2023-6916 has been assigned to this vulnerability. A CVSS v3 base score of 7.2 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H). 3.2.2 IMPROPER INPUT VALIDATION CWE-20 A Denial of Service (Dos) vulnerability in Nozomi Networks Guardian, caused by improper input validation…Read More